To obtain a full time position or an internship where I can maximize my experiences in diagnosing, repairing, installing, testing, maintaining and retrofitting commercial/industrial HVACR equipment, piping systems and control systems, in improving operating efficiency of HVACR systems, calculating building loads using building simulation software, engineering drafting using AutoCad, supervising day to day activities of subcontractors and five employees, implementing cost control measures with subcontractors and employees, procuring HVAC equipment, switchgear and parts, recommending, estimating and managing projects, complying with EPA and company environmental policies and procedures, hiring, training and providing excellent customer service.
CAREER OBJECTIVE
To obtain a full time position or an internship where I can maximize my experiences in diagnosing, repairing, installing, testing, maintaining and retrofitting commercial/industrial HVACR equipment, piping systems and control systems, in improving operating efficiency of HVACR systems, calculating building loads using building simulation software, engineering drafting using AutoCad, supervising day to day activities of subcontractors and five employees, implementing cost control measures with subcontractors and employees, procuring HVAC equipment, switchgear and parts, recommending, estimating and managing projects, complying with EPA and company environmental policies and procedures, hiring, training and providing excellent customer service.
WORK EXPERIENCE
March 05, 2007 HVAC Lead Technician, Viox Services
October 30, 2009 (Michigan, North Carolina)
• Operated, diagnosed, repaired and maintained sensors, controllers and final controlled devices, 500 ton York and Trane Chillers, 140 ton Rooftop units, 2 million Btuh Cleaver Brooks Firetube hot water boilers, water piping systems and Ingersoll Rand Air compressor systems.
• Diagnosed, maintained and repaired BAS field devices and controls for Metasys, Trane Veritrac and PLC’s
• Operated, Scheduled and performed basic programming of the Metasys BMS by utilizing a GUI workstation.
• Diagnosed, repaired and maintained critical Liebert DX systems for Arvin Meritor Global Data center
• Calculated building loads for critical areas such as computer rooms
• Programmed chiller and critical system controllers, cooling tower VFD’s, boiler schedule controllers and mixing valve controllers.
• Recommended and implemented projects to improve operation of HVAC systems and increase energy savings at both the ArvinMeritor Michigan World headquarters buildings and the 600 000 sq ft North Carolina Heavy Axle manufacturing facility
• Created equipment records of refrigerant type and amount, and maintained refrigerant log books for ArvinMeritor Environmental safety program.
• Operated and tested Fire Alarm systems, Emergency generators and dock equipment.
• Practiced safe waste oil disposal, security, personal and equipment safety
• Directed and coordinated subcontractors and employees
• Performed cost control with subcontractors and HVAC employees on projects and maintenance programs
• Hired HVAC technicians and trained them
May 2006 to HVACR Service Technician, SAMCO
January 2007 (Dearborn, Michigan)
• Repaired, maintained and installed HVACR commercial equipment up to 80 ton cooling capacity
• Recommended and estimated new projects
• Performed hands on supervision duties on new install and repair jobs
November 2005 HVAC Technician, Blue Dot Services
to May 2006 (Livonia, Michigan)
• Repaired and maintained HVAC commercial equipment up to 20 ton cooling capacity, boilers up to 2.5 million Btuh and makeup air units up to 3 million input Btuh
• Recommended and provided written estimates
• Performed hands on supervision duties on maintenance and repair jobs
April 2004 to HVAC Service Technician, Thermal Services
August 2005 (Birmingham, Michigan)
• Repaired and maintained HVAC commercial/industrial/health sector equipment up to 60 ton capacity and critical Liebert DX systems
• Repaired DDC, VAV, VVT, VFD, electrical, electronic and pneumatic control systems
• Troubleshot, repaired and maintained Carrier Comfort network field devices using ComfortVIEW interface.
• Performed equipment retrofits to ignition control systems
• Recommended and provided written estimates
• Communicated directly with Facility managers and employees
• Installed and started up gas fired furnaces and split systems
September 2003 HVAC Technician, Blue Dot Services
to April 2004 (Livonia, Michigan)
• Repaired and maintained HVAC residential equipment
• Installed Smoke detection systems
• Recommended and provided written estimates
• Recommended and sold preventative maintenance contracts
EDUCATION
2009 LEED Accredited Professional- New Construction, ID # 5F3C7EE19A, Green Building Certification Institute
2006 to 2010 Bachelor of Applied Science, major in
HVACR Engineering Technology, 3.27 GPA, Ferris State University, Michigan: Core courses completed
2003 to 2005 Associates in Applied Science degree, major in HVAC,
Henry Ford Community College, Dearborn, Michigan
1994 to 1996 Associates in Applied Science degree, major in Mechanical Engineering technology, Harare Polytechnic College, Zimbabwe
2006 to present Mechanical Contractor License, Michigan, License # 7115748
2006 to present ASHRAE, Member # 8036268
2003 EPA Universal Certification
NukeJobs is a nuclear jobs board that provides nuclear job seekers access to international directories of Nuclear Employers, Nuclear Resumes and Nuclear Jobs such as Nuclear Engineer Jobs, Nuclear Construction Jobs, Nuclear Power Plant Jobs, Nuclear Medicine Jobs, Nuclear Pharmacy Jobs, Nuclear Security Jobs, Nuclear Physics Jobs, Nuclear Reactor Jobs, Nuclear Material Jobs, Nuclear Safety Jobs, and Nuclear Waste Jobs.