Objective A position using engineering, maintenance and mechanical expertise in a team
Environment.
Profile
 LOGCAP III in Afghanistan, contractor.
 Proven ability to maintain buildings and mechanical equipment, including contracting
outside services, troubleshooting, and handling tenant requests professionally.
 Comprehensive experience in the repair and maintenance of motors, control panels, and
major mechanical and electrical systems, including timers, circuit breakers, feeders,
coils, and relays.
 Experience in commercial and residential electrical wiring, repair, and maintenance, as
well as mechanical-system troubleshooting.
 Effectively train staff in system repairs, operations, and procedures; use of multi-meters;
familiar with Microsoft Windows for data entry and retrieval.
 Texas state licensed Master Electrician; proficient in HVAC systems: refrigeration, air
conditioning, heating, and related electronics.
Education & Training
Building Owners & Managers Institute International 2007-2008
Classes:
 Electrical Systems and Illumination
 Refrigeration Systems and Accessories
Independent Electrical Contractors School 2001-2005
 Texas State Master Electrician
CPR/First Aid and AED certified
TWIC Card
Technical Experience
Master Electrician 2009-Current
QA/QC Master Electrician 2008-2009
KBR, Bagram, Afghanistan
 Military Airbase Quality Assurance Quality Control.
 Electrical Grounding and Bonding Validation on more than 3500 structures on base.
 Quality Audit Inspection Report review and approval for 26 QA/QC Electricians
throughout Afghanistan.
 12 hours a day 7 days a week work schedule, Hostile work environment
 O&M and Construction, Facilities maintenance for combat hospital
Sr. Building Engineer, Electrical 2006-2008
Countrywide Home Loans, Fort Worth, TX
 Responsible for contributing towards the delivery of 24/7 operation, maintenance and
repair of Countrywide Tier 3 data center and facility in respect to all facets of the HVAC, mechanical, electrical, fire alarm/suppression, and related infrastructure systems.
 Ensured facility compliance with federal, state and local regulatory agencies
(EPA, OSHA, etc).
 Operated and regularly tested 3 2megawatt emergency generators, UPS and automatic transfer
switches.
 Responded to electronic communication on an as needed basis to facility emergencies,
24/7.
 Operated and monitored the Building Automation System performing corrective action
when necessary.
Journeyman electrician/Master Electrician 2000-2005
Design Electric, Fort Worth TX
 Estimating, Project management, Design Build, directed field hands in appropriate
electrical installation.
 Coordinated with utility, phone, and fire alarm companies.
 Prepared proposals, load calculations, one-line drawings, and daily correspondence,
Attended on site meetings with all trades.
 Procured material and equipment solved all installation problems.
NukeJobs is a nuclear jobs board that provides nuclear job seekers access to international directories of Nuclear Employers, Nuclear Resumes and Nuclear Jobs such as Nuclear Engineer Jobs, Nuclear Construction Jobs, Nuclear Power Plant Jobs, Nuclear Medicine Jobs, Nuclear Pharmacy Jobs, Nuclear Security Jobs, Nuclear Physics Jobs, Nuclear Reactor Jobs, Nuclear Material Jobs, Nuclear Safety Jobs, and Nuclear Waste Jobs.